Customization: | Available |
---|---|
Condition: | New |
Certification: | ISO, CE |
Still deciding? Get samples of US$ 50/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ITEM | MODEL | HT60D-4048 |
Rated charge current | 40A | |
Rated load current | 40A | |
System voltage | 48VDC | |
Protection | Over Load | ≥120%, 60s;≥150%,10s,≥180%,0.2s |
Short circuit | Yes | |
Over voltage | 16V for 12VDC,32V for 24VDC,64V for 48VDC | |
Low Voltage Disconnection(LVD) | 10.8V for 12VDC, 21.6V for 24VDC,43.2V for 48VDC | |
Low Voltage Reconnection(LVR) | 12.6V for 12VDC,25.2V for 24VDC,50.4V for 48VDC | |
Reverse polarity | protection for solar panel ,battery and DC load. | |
Reverse current | Yes.at night | |
Static current | ≤15mA | |
Loop Voltage Drop | Charge / Discharge | ≤0.17V /≤0.10V |
Charging voltage | absorption charging | 14.4V for 12VDC,28.8V for 24VDC,57.6V for 48VDC |
Float charge | 13.8 for 12VDC,27.6V for 24VDC,55.2V for 48VDC | |
Open Circuit Voltage of solar panel | 12VDC/24V ≤50V;48V ≤100V | |
Temperature compensation | -4mV/Cell/ºC | |
Charging control mode | PWM Multi-stage(bulk, absorption,float) | |
Load Working Mode | regular mode, Light Control Mode , Light and Time control mode for selection | |
LCD Display | LCD for Bat type,VDC,PV output VDC,Amp and Accumulative charge AH.Load Amp and Accumulative discharge AH,Battery charge and discharge value. Controller internal Temp,fault code and S/N. load Time and light control status | |
USB Charge | NO | |
Running temperature | -20 ~ +55 °C | |
Storage temperature | -30 ~ +80 °C | |
Humidity requirements | 10% -90%, no condensation | |
Installation cable area | ≤25mm2 | |
Protection class | IP30 | |
Case material | ABS | |
Product size(mm) | 196*111*54 | |
Product Weight(kg) | 0.407 | |
Carton size(mm) | 535*415*190 | |
Carton weight(kg) | 14KG /24PCS | |
Notes | Model HT**D:D-LCD, 24-12V/24VDC, 48-- 48VDC |