Low Frequency Online UPS
TC 10-120KVA, 8-96KW
KEY FEATURES
- Three phase in, three phase out
- Microprocessor control
- 100% unbalance protection design
- True on-line double conversion design providing all power protection
- Isolated output
- Sine wave pulse width modulation
- IGBT inverter design.
- Wide Input voltage windows
- Pure sine wave output less than 3% THD
- Expandable battery run time
- Generator compatible
- Cold start
- Load/Battery power meter display
- Overload, on-line, battery status LED/LCD
- Advanced Battery Management
- Automatic charging in UPS off mode
- Smart RS-232 communication port
- Optional SNMP card
Technical Specifications
MODEL |
TC10K |
TC15K |
TC20K |
TC30K |
TC40K |
TC60K |
TC80K |
TC100K |
TC120K |
Capacity |
10KVA |
15KVA |
20KVA |
30KVA |
40KVA |
60KVA |
80KVA |
100KVA |
120KVA |
Power |
8KW |
12KW |
16KW |
24KW |
32KW |
48KW |
64KW |
80KW |
96KW |
Power Factor |
0.8 |
Input |
Phase |
3 phase 4 wire and ground |
Voltage Range |
380V±20%(3 phase), phase voltage 220V |
Frequency Range |
45 - 65Hz |
Rectifier |
3 phase 6 pulses, 12 pulses is optional |
Output |
Phase |
3 phase 4 wire and ground |
Wave Form |
Pure sine wave |
Crest Factor |
3:1 |
Rated Voltage |
380/400/415V optional,+ -1% for static load, 5% for fluctuant load |
Phase Voltage Setting |
200 - 244VAC, pls confirm when order |
Transient Response |
+/-5%, 10ms |
Frequency |
50 / 60 Hz + / - 0.05% |
Total Harmonic Distortion |
< 3%(linear load, < 5%( nonlinear load) |
Short Circuit Current |
Short current for 0.1s (200% current) |
Overload Capacity |
Overload 125% for 10 Mins, 125%-150% for 1min .automatically resume when load become normal |
Battery |
Battery |
Maintenance free lead-acid cell |
DC Voltage |
384VDC |
396VDC |
Max Charge Current |
6-30A adjustable |
Bypass |
Type |
Static state + manual maintenance bypass |
Input Phase |
3 phase 4 wire and ground |
Input Voltage Range |
15% - 25% (the front control panel selectable) |
Transfer Time |
Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms |
Efficiency |
Whole Unit |
>80% |
|
Inverter |
91 |
91 |
92 |
92 |
93 |
93 |
95 |
95 |
95 |
Remote signaling |
Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA,Optional parts |
Communication interface |
RS232 ( SNMP , modem optional ) |
Running temperature |
0-40 degree Celsius |
Relative Humidity |
Less than 95% (without condensing) |
Noise at 1 M |
less than 60 dB |
Degree of protection |
IP20 |
Applicable Standards |
EN50091-1-EMC EN50091-2liv.A |
Product size(mm) |
780*580*1170 |
1000*660*1450 |
1200*900*1820 |
product weight(Kg) |
180 |
220 |
250 |
300 |
400 |
470 |
640 |
740 |
740 |
Package size(mm) |
945*745*1395 |
1135*810*1755 |
1450*1110*1880 |
Package weight(Kg) |
200 |
270 |
300 |
350 |
480 |
550 |
700 |
800 |
800 |
PRODUCT DISPLAY