| ITEM |
MODEL |
HT4830DU |
HT4840DU |
HT4850DU |
HT4860DU |
HT2450DU |
HT2460DU |
| Rated charge current |
30A |
40A |
50A |
60A |
50A |
60A |
| Rated load current |
30A |
40A |
50A |
60A |
50A |
60A |
| System voltage |
12/24/48V AUTO work |
12/24V AUTO work |
| Protection |
Over Load |
≥120%, 60s;≥150%,10s,≥180%,0.2s |
| Short circuit |
Yes |
| High Voltage Disconnection(HVD) |
16.5V for 12VDC,Else is multiple |
| Low Voltage Disconnection(LVD) |
11V for 12VDC ,Else is multiple |
| Low Voltage Reconnection(LVR) |
12.6V for 12VDC,,Else is multiple |
| Reverse polarity |
protection for solar panel ,battery and DC load. |
| Reverse current |
Yes.at night |
| Static current |
≤10mA |
| Charging voltage |
absorption charging |
14.4V for 12VDC, 28.8V for 24VDC,57.6V for 48VDC,2hours |
| Float charge |
13.8 for 12VDC,27.6V for 24VDC,55.2V for 48VDC |
| Equalizing charging |
14.6V for 12VDC,29.2V for 24VDC,58.4V for 48VDC, 2hours |
| Charging control mode |
PWM 4-stage(bulk, absorption,float, equalized) |
| Battery type |
Sealed, GEL, Flood and Usr (default) |
| Open Circuit Voltage of solar panel |
55V |
| Temperature compensation |
-24mV/Cell/ºC for 12V system |
| USB Charge |
2*5V 1.0A |
| LCD/LED Display |
LCD for Bat type,VDC,,PV output VDC,Amp and Accumulative charge AH.Load Amp and Accumulative discharge AH,Battery charge and discharge value. Controller internal Temp,fault code and S/N. load Time and light control status |
| Load Working Mode |
regular mode, Light Control Mode , Light and Time control mode for selection |
| Running temperature |
-20 ~ +55 °C |
| Storage temperature |
-30 ~ +80 °C |
| Humidity requirements |
10% -90%, no condensation |
| Installation cable area |
28---10 AWG |
| Protection class |
IP32 |
| Case material |
ABS |
| Product size(mm) |
192.5*109*43 |
200*126*56 |
| Product Weight(kg) |
0.396 |
0.636 |
| PCS/CTN |
30 |
24 |
| Carton size(mm) |
430*365*275 |
438*380*285 |
| Carton weight(kg) |
15.3 |
17 |
| Notes |
Model HT**DU:D-LCD,U-5V/1A USB, 24-12/24VDC, 48-12/24/48VDC |