Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | NST55- 300LF(C ) | NST55- 500LF(C ) | NST110- 500LF(C ) | NST110- 1000LF(C ) | NST220- 500LF(C ) | NST220- 1000LF(C ) | NST220- 1500LF(C ) | ||||
AC output | Rated Power(W) | 300 | 500 | 500 | 1000 | 500 | 1000 | 1500 | |||
voltage(VAC) | 110V/120V,220V/230V | ||||||||||
frequency(Hz) | 50HZ,60HZ | ||||||||||
Wave form | Sine Wave | ||||||||||
AC output switch | yes | ||||||||||
Battery | Battery bank voltage | 12VDC | 24VDC | 24VDC | |||||||
Internal battery | 1*GEL55AH-12VDC | 2*GEL55AH-24VDC | 4*GEL55AH-24VDC | ||||||||
Extension Battery connector | Advice 12VDC , 55AH Mode | Advice 2PCS GEL55-12 in series | Advice 4PCS GEL55-12,2 series 2 parallel | ||||||||
Recharge time | within 3hours | within 3hours | within 6horus | ||||||||
Battery switch | yes , Breaker | yes , Breaker | yes, Breaker | ||||||||
Grid Charger (Option) | AC charge Range | 110V or 220V +- 25% | 110V or 220V +- 25% | 110V or 220V +- 25% | |||||||
Charge current | 12VDC10AMP | 24VDC5AMP | 24VDC5AMP | ||||||||
Grid charge switch | yes | yes | yes | ||||||||
Charge Controller | Max Current | 30A | 30A | 30A | |||||||
Rated VDC | 12VDC | 24VDC | 24VDC | ||||||||
Input range | 10V to 25VDC | 20V to 50VDDC | 20V to 50VDDC | ||||||||
Equalizing Charge Voltage | 14.3VDC | 28.6V | 28.6V | ||||||||
Float voltage | 13.7VDC | 27.4VDC | 27.4VDC | ||||||||
Over charge protective voltage(VDC) | 14.2VDC | 28.4VDC | 28.4VDC | ||||||||
Over charge recover voltage(VDC) | 14VDC | 28VDC | 28VDC | ||||||||
Solar panel | adviced capacity | 36Cell, max 500WP | 36Cell in series or 72 Cell max 1000WP | 36Cell in series or 72 Cell max 1000WP | |||||||
PV input Terminal | yes | yes | yes | ||||||||
DC output | high voltage protective voltage(VDC) | 16VDC | 32VDC | 32VDC | |||||||
High voltage recover voltage(VDC) | 15.2VDC | 30.4VDC | 30.4VDC | ||||||||
Low voltage recover voltage(VDC) | 12.6VDC | 25.2VDC | 25.2VDC | ||||||||
Low voltage protective voltage(VDC) | 11VDC | 22VDC | 22VDC | ||||||||
5VDC USB Output | 2 Port,/MAX 2A | 2 Port,/MAX 2A | 2 Port,/MAX 2A | ||||||||
Big DC output | 8AMP, 12VDC | 8AMP, 12VDC | 8AMP, 12VDC | ||||||||
12VDC DC Lamp port | 2 Port,/MAX 2A | 2 Port,/MAX 2A | 2 Port,/MAX 2A | ||||||||
DC output general switch | yes | yes | yes | ||||||||
Display | LED display | solar charge status/Bat voltage normal,over hgih,over low,charge protection/ /DC output ON,OFF,overload, short circuit/ Inverter overload,short circuit,fault | |||||||||
Digital Display | Battery VDC, Output VAC | ||||||||||
Alarm | overload bat low , alarm /1sec; battery low or high protection,alarm/3 sec,inverter short circuit or fault,continous | ||||||||||
Fan start temperature | >45ºC | ||||||||||
Operation environment temperature | 0-40ºC | ||||||||||
Working temperature | -25 - +55ºC | ||||||||||
Humidity | 0-90%non-condensing | ||||||||||
Product Size:D*W*H(mm) | 343*225*443 | 423*260*453 | 513*310*493 | ||||||||
Packed Size:D*W*H(mm) | 420*290*490 | 520*370*520 | 610*420*550 | ||||||||
G.W of the package with bat | 26.7 | 28.4 | 42.9 | 47.6 | 76.9 | 82.2 | 86.7 | ||||
Remark | Internal Battery backup time | The above is around value under Full load. actual using should not always full load. So should be longer . Can Extension Battery again . | |||||||||
Recharge time | the above based on max PV and use the AC/DC power Charger too .actual using is different for solar panel capacity reason | ||||||||||
Mode name | NST55-300LF(C ),N- new, ST-Solar Trolley,300W,55-55AH/12VDC, C , with AC/DC Grid Charger |