ITEM |
Model |
N-SUB1500 |
N-SUB3000 |
N-SUB3500 |
N-SUB5000 |
N-SUB5500 |
N-SUB5000P |
INPUT |
RATED POWER |
1.5KW |
3KW |
3.5KW |
5KW |
5.5KW |
5KW |
Voltage |
230 VAC |
Selectable Voltage Range |
170-280 VAC (For Personal Computers) |
90-280 VAC (For Home Appliances) |
Frequency Range |
50 Hz/60 Hz (Auto sensing) |
OUTPUT |
Voltage |
230VAC ± 5%(Bat Mode) |
Surge Power |
2 times Rated power for 5 seconds |
Overload Protection |
5s@≥150% load; 10s@110%~150% load |
Efficiency,PV to INV. |
97% (Peak) |
Efficiency,Battery to INV. |
94%(Peak) |
Transfer Time |
10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
Battery type |
AGM/Flooded/user defined , Lithium ( need to mention when needed ) |
BATTERY & AC CHARGER |
Battery Voltage |
24 VDC |
24 VDC |
24 VDC |
48 VDC |
48 VDC |
48 VDC |
Floating Charge Voltage |
27 VDC |
27 VDC |
27 VDC |
54 VDC |
54 VDC |
54 VDC |
Overcharge Protection |
33 VDC |
33 VDC |
33 VDC |
63 VDC |
63 VDC |
63 VDC |
Charge Current (Max) |
60A |
80 A |
80A |
80 A |
80A |
80 A |
SOLAR CHARGER |
PV Array Power (Max) |
2000W |
4000W |
5KW |
5000W |
6KW |
5000W |
MPPT Range |
120 ~ 450 VDC |
PV Array VOC (Max) |
500 VDC |
Charging Current (Max) |
80A, AC+Solar adjustable |
80A, AC+Solar adjustable |
Max100A AC+Solar |
80A, AC+Solar adjustable |
Max100A AC+Solar |
80A, AC+Solar adjustable |
Efficiency (Max) |
0.98 |
Display |
LED |
Line Mode or bat Mode, Charging status ,Fault |
LCD |
Vac HZ, Charge Amp W, PV VDC Amp W , Load % VA W Amp ,bat % VDC ,,setup , Fault code, working mode, |
Setup/Adjust parameter |
Solar power /utility power/Battery priority, united Charge Current , AC Charge Amp, AC input range, VAC HZ, Bat VDC back to utility power, BAT VDC back to Bat Mode, Charge Source select ,Alarm on off , overload bypass, Bulk/ Floating Charge VDC, Bat Low Cut VDC , equalization Charge VDC / mins / days, |
Output working Mode |
utility power priority |
default. Utility power priority, Solar and battery as backup when utility power not available |
Solar priority(SUB Mode) |
solar power priority, utility power supplement to load when solar power is not enough , utility not available, battery supplement to load. Working on daytime while No Bat |
SBU priority |
Solar power priority, When Solar power is not enough,battery to supplement.when battery power is not enough , utility power to load. Working on daytime while No Bat |
Product size |
L*W*H |
448*295*105mm |
Net Weight (kgs) |
Kg |
8.5 |
9 |
9 |
10 |
10 |
10 |
Carton size |
L*W*H |
590*390*208mm |
Carton weight |
Kg |
11 |
11 |
11 |
11.8 |
11.8 |
11.8 |