Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Model | XG6K | XG6KS | XG10K | XG10KS | XG15K | XG15KS | XG20K | XG20KS |
Capacity | VA / Watts | 6KVA / 4.8KW | 6KVA / 4.8KW | 10KVA / 8KW | 10KVA / 8KW | 15KVA/12KW | 15KVA/12KW | 20KVA/16KW | 20KVA/16KW |
Input | Normal Voltage | 220VAC | |||||||
Turn On Voltage Range | (120±5~274±5)VAC | ||||||||
Frequency Range | 40~60Hz+-0.2(adjustable) | ||||||||
Input Power Factor | >0.99(220VAC,full R load) | ||||||||
Generator | Support generator input(Generator rating≥2*UPS rating ) | ||||||||
Line Low Loss/ComeBack | 220VAC:(120±5)VAC/(140±5)VAC when Load≤50% | ||||||||
220VAC:(150±5)VAC/(165±5)VAC when 50%< Load≤80% | |||||||||
220VAC:(160±5)VAC/(175±5)VAC when 80%< Load | |||||||||
Output | Voltage Range | 200VAC/208VAC/220VAC/230VAC/240VAC, need to confirm before order(Could be adjusted by software,10% derating for 208VAC/200VAC) | |||||||
Frequency Range | 40~60Hz+-0.2(adjustable) | ||||||||
Wave Form | Pure Sine Wave | ||||||||
Transfer Time | 0 ms, Between Line mode and Bat mode | ||||||||
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode | |||||||||
Voltage Distortion | ≤6%,Full RCD load | ||||||||
Voltage Distortion | ≤2%,Full R load | ||||||||
Overload Capacity | load≤105%±5%, warning only, 105%+-5%<Load≤125% +-5% ,1min ; 125%±5%<load≤135%±5% , 30S ; Load>135%±5%, 100MS | ||||||||
Load Peak Ratio | 3:1(max) | ||||||||
Battery | Battery Type | Maintenance free valve regulated lead acid (VRLA) battery | |||||||
Battery Voltage | 192VDC or 240VDC | ||||||||
Battery Capacity | 16*7A or 20*7AH, 9AH Option | External | 16*7A or 20*7AH, 9AH Option | External | 20*9AH, 7Ah option | External | 20*9AH, 7Ah option | External | |
Recharge Time | 7 hours to 90% capacity | Depended on battery capacity |
7 hours to 90% capacity | Depended on battery capacity |
7 hours to 90% capacity | Depended on battery capacity |
7 hours to 90% capacity | Depended on battery capacity |
|
Charge Current | 1 or 2.5A | Normal 5Amp. Max 7Amp | 1 or 2.5A | Normal 5Amp. Max 7Amp | 1 or 2.5A | Normal 5Amp. Max 7Amp | 1 or 2.5A | Normal 5Amp. Max 7Amp | |
Display | LED Display | Line , Inverter , Bypass, battery | |||||||
LCD Display | LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. Fault Code ,LED for line,bat, Inverter, Bypss,Fault | ||||||||
Audible Alarm | Battery Mode | Beeping every 4 min (re-settable) | |||||||
Overload | Beeping every 1 min | ||||||||
Fault | Beeping Continuously | ||||||||
Bettery Low/Charger Fault | Beeping every 1 min | ||||||||
Bypass Mode | Beeping every 2 min | ||||||||
L/N Inverse | Beeping every 2 min | ||||||||
Communications | RS-232/USB Interface | RS232 or USB, With monitoring software | |||||||
Working Environment | Surge Protection | RJ-45 I/O port available for network or Fax/Modem | |||||||
Working Temperature | 0ºC~40ºC | ||||||||
Humidity | 0-95% non-condensing | ||||||||
Product size | WxDxH (mm) | 260*533*560 | 190*425*328 | 260*533*560 | 260*533*501 | 560*260*717 | 533*260*501 | 560*260*717 | 533*260*501 |
Product Weight | Kg | 55/63(7AH) | 12.2 | 62/70(9AH) | 21 | 83(9AH) | 32 | 84(9AH) | 33 |
PCS/CTN | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
CTN size | WxDxH (mm) | 360*640*760 | 295*565*445 | 360*640*760 | 395*690*650 | 705*430*960 | 640*360*760 | 705*430*960 | 640*360*760 |
CTN Weight(G/W) | Kg | 65/73(7AH) | 14.3 | 72/80(9AH) | 24 | 92(9AH) | 35 | 96(9AH) | 36 |
REMARK | XG*K --- Standard Type Internal battery, XG*KS---- Long backup Type,External battery |