Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room

Product Details
Customization: Available
Phase: Three Phase
Type: On-line
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM/ODM Availability
Yes
  • Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room
  • Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room
  • Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room
  • Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room
  • Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room
  • Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
RM120-600
Application
Industry
Classification
Lighting/Power
Standby Time
Long-acting Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Kemapower
Transport Package
Safety Packing
Specification
Modular UPS
Trademark
KEMAPOWER
Origin
China
HS Code
8504403090
Production Capacity
60, 000PCS/Year

Product Description

 

PM60 3PH Rack Module UPS

Product Description

 

KEY FEATURES

  1. Power Module 60K Rack Module UPS 120K/180K/240K/300K/480K/600K
  2. High effciency over 94.5% at 50% load, Output Power Factor 1 technology
  3. DSP control, ,online double conversion,Integrated modular and parallel technology
  4. High scalability,Single rack expanding 120KVA to 600KVA, N+1 or N+X redundancy in the same rack, supports 1+1 cabinet parallel operation.
  5. Built-in maintenance bypass, praevia all panel control and connectors
  6. Highly reliable operation with redundant power supply in STS
  7. High overload Capacity ,  60mins@110%, 10Mins@125% ,1mins@150%
  8. 32 to 40PCS adjustable Battery numbers
  9.  Adiustable charging current,Max 18A


TECHNICAL SPECIFICATIONS

MODEL RM120/60X30U-RYY RM180/60X30U-RYY RM240/60X-RYY RM300/60X-RYY RM480/60X42U-RYY RM600/60X42U-RYY
PHASE 3-phase in/3-phase out
CABINET CAPACITY* 120KW 180KW 240KW 300KW 480KW 600KW
BATTERY TYPE External Battery
One Power Module Capacity 60KVA/60KW
Max. Power Module No. 2 3 4 5 8 10
INPUT
Nominal Voltage 380VAC/400VAC/415VAC (3Ph+N)
Voltage Range 305 ~ 478 VAC at 70% - 100% load; 208 ~ 478VAC for <70% load
Nominal Frequency 50/60Hz (Auto sensing)
Frequency Range 40Hz ~70Hz
Power Factor > 0.99 at 100% load, >0.98 at 50% load
Harmonic Distortion (THDi) < 3% @ 100% load
OUTPUT
Nominal Voltage 380VAC/400VAC/415VAC (3Ph+N)
Voltage Regulation       (Steady State) <=± 1% Typical (balanced load)
<=± 2% Typical (unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range (Synchronized Range) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability 110% for 1 hour,  125% for 10 mins  , 150% for 1 min   and 200ms for >150%
Harmonic Distortion <= 2% THD (Linear Load)
<= 4% THD (Non-linear Load)
Efficiency Up to 96%
BATTERY / CHARGER
Nominal Voltage +/-  192V~+/- 240V  (Selectable)
Maximum Voltage +/- 240V (12V x 40 Pcs)
Minimum Voltage +/- 192V (12V x 32 Pcs)
Floating Charge Voltage 2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current (Per Power Module) 18A
PHYSICAL
Cabinet Dimension
(D x W x H) mm
1100 x 600 x 1475 1100 x 600 x 2010 1065 x 1000 x 2000
Net Weight (kgs) 308 352 516 516 932 1020
ENVIRONMENT
Operation Temperature 0 ~ 40ºC
Relative Humidity 0 ~ 95% non-condensing
Altitude* <1000m for Nominal power
IP Class IP 20
MANAGEMENT
RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 60950-1; IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3

*If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.

Model Description Dimension DxWxH(mm) Weight (kg)
PM-60 3P/3P 60KVA60KW power module 750 x 438 x 133 (3U) 44
Detailed Photos


Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room
 

Company Profile

Modular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer RoomModular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer RoomModular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer RoomModular Online UPS 5kVA Pure Sine 20 Kw Online UPS Type 380V 120kVA Modular UPS for Computer Room


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier